In this section...
PRODUCTS
SUPPLIES
|
|
|
Safety
IEC60601-1 approved, CE marking according to MDD93/42/EEC
Dimension and Weight
Dimension: 318mm (W) x 264mm (H) x 152mm (D)
Weight: 5.4kg
Operation Environment
Power Requirements: AC100-250V, 50/60 Hz
Temperature: 0-40
Humidity: 30-85%
Application Scope
Adult, pediatric and neonatal
Performance Specifications
Display: 12.1h color TFT
Resolution: 800x600
Trace: 8 waveforms
Sweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
Indicator: Alarm indicator light
Power indicator light
QRS beep and alarm sound
Interface: Net Port
Battery: Rechargeable
Trend time: 1~72 hours
Alarm: 3-level audible and visual alarm
Networking: Only connected to Mindray Hypervisor V central monitoring system
Recorder: Built-in, thermal array, 2 channels
Record width: 48mm, (record paper 50mm)
Record speed: 25mm/s, 50mm/s
ECG
5-lead and 3-lead selectable
Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
3-lead: RA; LA; LL or R; L; F
Lead selection: 5-lead: I; II; III; avR; avL; avF; Vx
3-lead: I; II; III
ECG waveform: 2 channels
Gain selection: x0.25; x0.5; x1; x2; auto
Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
Heart Rate range: Adult: 15-300bpm;
Pediatric/Neonatal: 15-350bpm
Accuracy: }1bpm or }1%, whichever is greater
Resolution: 1bpm
Protection: Withstand 4000VAC/50Hz voltage in isolation
Against electrosurgical interference and defibrillation
CMRR: Diagnostic mode: >90dB
Monitoring mode: >105dB
Operating mode: >105dB
Calibration signal: 1mV}5%
Bandwidth: 0.05-100Hz
Alarm range: Adult:15-300bpm
Pediatric/Neonatal: 15-350bpm
S-T detection: YES
Measurement range: -2.0mV~2.0mV
Alarm range: -2.0mV~2.0mV
Arrhythmia analysis: YES
Alarm: YES, audible and visual alarm, alarm events recallable
Respiration
Method: RA-LL impedance
Measurement range: Adult: 6~120rpm;
Pediatric/Neonatal: 6~150rpm
Resolution: 1 rpm
Accuracy: }2 rpm
Alarm range: Adult: 6~120rpm
Pediatric/Neonatal: 6~150rpm
Apnea alarm: YES
NIBP
Method: Oscillometric
Operation modes: Manual/Automatic/Continuous
Measurement unit: mmHg/Kpa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range: Adult: 10-270mmHg
Pediatric: 10-200mmHg
Neonatal: 10-135mmHg
Over-pressure protection: YES
Resolution: 1mmHg
Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10
Alarm: Systolic, Diastolic, Mean
SpO2
Measurement range: 0~100%
Resolution: 1%
Accuracy: }2digit (70-100%); 0-69% unspecified
Alarm range: 0~100%
Pulse rate: Range: 25~250 bpm
Resolution: 1 bpm
Accuracy: }2 bpm or }2%, whichever is greater
Alarm range: 25~250 bpm
Masimo SETTM SpO2
Range
Saturation (SpO2):
Pulse Rate:
Signal Strength (SS):
>0.2%
0.02 - 0.2%
0-100%
25-240 bpm
Transmission (dB)
> - 50
> -30 -100 x Signal Strength (%)
Accuracy
Adults
SpO2 Range
Accuracy (+1Std. Dev.)*
Pulse Rate Range
Accuracy (+1Std. Dev.)*
Neonates
SpO2 Range
Accuracy (+1Std. Dev.)*
Pulse Rate Range
Accuracy (+1Std. Dev.)*
70%-100% 0% to 69%
+ 2 digits Unspecified
25-240 BPM
+ 3 BPM
70%-95% 0% to 69%
+ 3 Digits Unspecified
25-240 BPM
+ 3 BPM
Temperature
Measurement range: 0~50
Resolution: 0.1
Accuracy: }0.2(including probe)
Channel: Dual-channel
Alarm range: 0-50
IBP
Measurement range: -10~300mmHg
Channel: 2 channels
Pressure transducer: Sensitivity: 5(V/V/mmHg)
Impedance range: 300-3000ohm
Transducer sites: ART, PA, CVP, RAP, LAP, ICP
Measurement unit: mmHg/Kpa selectable
Resolution: 1mmHg
Accuracy: }1mmHg or }2%, whichever is greater
Alarm range: -10~300mmHg
CO2
Method: Thermodilution
Measurement range: CO: 0.1-20 lit./min.
TB: 23-43
TI: 0-27
Resolution: CO: 0.1 lit./min.
Temperature: } 0.1
Accuracy: CO: }0.1Lit/min or }5%, whichever is greater
TB: }0.1
TI: }0.1
EtCO2
Method: Infrared Absorption
Measuring Mode: Sidestream or Mainstream (optional)
Measurement range: EtCO2: 0-99mmHg
InsCO2: 0-99mmHg
AwRR: 0-150rpm
Resolution: EtCO2: 1mmHg
InsCO2: 1mmHg
AwRR: 1rpm
Accuracy: CO2 concentration: }2mmHg (0-40mmHg)
}5% of reading (41-76mmHg)
}10% of reading (77-99mmHg)
AwRR: }2rpm
Alarm range: Same as Measurement range
Apnea alarm: YES
Multi-Gas/O2
Method: Infrared Absorption
Gas sorts: CO2, N2O, Des, Iso, Enf, Sev, Hal, O2 (optional paramagnetic sensor)
Measurement range: CO2: 0~10% (0~76mmHg)
N2O: 0~100%
O2: 0~100%
Enf, Iso, Hal: 0~5%
Sev: 0~8%
Des: 0~18%
Data output: Fi and Et values
Respiration rate: 4~60 }1bpm
Other: Up to 3 waveforms displayed
Agent mixture detection
MAC value displayed
|
|